{"id":8,"date":"2018-02-21T18:36:36","date_gmt":"2018-02-21T17:36:36","guid":{"rendered":"https:\/\/ophthalmo-pro.de\/en\/?page_id=8"},"modified":"2021-11-10T16:52:26","modified_gmt":"2021-11-10T15:52:26","slug":"primus-hd","status":"publish","type":"page","link":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/","title":{"rendered":"Primus-HD\u00ae \/ Yellow"},"content":{"rendered":"\t
\n\t\t\r\n\t
\n\t\t\r\n\t
\n\t\t

Primus-HD\u00ae (clear)<\/h1>\t<\/div>\n\t\r\n\t
\n
<\/div>\n
<\/div>\n
<\/div>\n
<\/div>\n <\/div>\n\t\r\n\t
\n\t\t

1-Step-Preload in perfection: Clear IOL, aspherical<\/h4>\t<\/div>\n\t\r\n\t
\n
<\/div>\n
<\/div>\n
<\/div>\n
<\/div>\n <\/div>\n\t\r\n\t
\n\t\t

The benefits at a glance:<\/h4>\t<\/div>\n\t\r\n\t
\n\t\t
    \n
  • Aspherical optics (aberration correcting -0.20 \u00b5)<\/li>\n
  • Optics with posterior-convex design<\/li>\n
  • Hydrophobic acrylate \u2013 glistening-free \u2013 grade \u201e0\u201c on the Miyata scale<\/li>\n
  • 360\u00b0 continuous, sharp edge<\/li>\n
  • Haptics angled at 1.5\u00b0<\/li>\n
  • Modified C-loop<\/li>\n
  • UV filter<\/li>\n
  • Refractive index 1.48 at 35\u00b0<\/li>\n
  • 13 mm total diameter<\/li>\n
  • 6 mm optic diameter<\/li>\n
  • Dptr. -10.0 to + 36.0 in 0.5 steps \u2013 all dptr. preloaded<\/li>\n<\/ul>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
    \n\t\t\r\n\t
    \n\t\t\r\n\t
    \n
    <\/div>\n
    <\/div>\n
    <\/div>\n
    <\/div>\n <\/div>\n\t\r\n\t\t\t
    \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
    \n
    <\/div>\n
    <\/div>\n
    <\/div>\n
    <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
    \n\t\t\r\n\t
    \n\t\t\r\n\t
    \n\t\t

    Primus-HD\u00ae Yellow<\/span><\/h1>\t<\/div>\n\t\r\n\t
    \n
    <\/div>\n
    <\/div>\n
    <\/div>\n
    <\/div>\n <\/div>\n\t\r\n\t
    \n\t\t

    1-Step-Preload in perfection: IOL with blue light filter, aspherical<\/h4>\t<\/div>\n\t\r\n\t
    \n
    <\/div>\n
    <\/div>\n
    <\/div>\n
    <\/div>\n <\/div>\n\t\r\n\t
    \n\t\t

    The benefits at a glance:<\/h4>\t<\/div>\n\t\r\n\t
    \n\t\t
      \n
    • Aspherical optics (aberration correcting -0.20 \u00b5)<\/li>\n
    • Optics with posterior-convex design<\/li>\n
    • Hydrophobic acrylate \u2013 glistening-free \u2013 grade \u201e0\u201c on the Miyata scale<\/li>\n
    • 360\u00b0 continuous, sharp edge<\/li>\n
    • Haptics angled at 1.5\u00b0<\/li>\n
    • Modified C-loop<\/li>\n
    • UV filter and integrated blue light filter (cut from 390 nm \u2013 470 nm)<\/strong><\/li>\n
    • Refractive index 1.48 at 35\u00b0<\/li>\n
    • 13 mm total diameter<\/li>\n
    • 6 mm optic diameter<\/li>\n
    • Dptr. -10.0 to + 36.0 in 0.5 steps \u2013 all dptr. preloaded<\/li>\n<\/ul>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
      \n\t\t\r\n\t
      \n\t\t\r\n\t
      \n
      <\/div>\n
      <\/div>\n
      <\/div>\n
      <\/div>\n <\/div>\n\t\r\n\t\t\t
      \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t<\/div>\n\t\r\n\t
      \n\t\t\r\n\t
      \n
      <\/div>\n
      <\/div>\n
      <\/div>\n
      <\/div>\n <\/div>\n\t\r\n\t\t\t
      \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
      \n\t\t\r\n\t
      \n\t\t\r\n\t
      \n
      <\/div>\n
      <\/div>\n
      <\/div>\n
      <\/div>\n <\/div>\n\t\r\n\t
      \n
      <\/div>\n
      <\/div>\n
      <\/div>\n
      <\/div>\n <\/div>\n\t\r\n\t
      \n\t\t

      Prosert\u00ae Preload Injector<\/h1>\t<\/div>\n\t\r\n\t
      \n
      <\/div>\n
      <\/div>\n
      <\/div>\n
      <\/div>\n <\/div>\n\t\r\n\t
      \n\t\t

      The self-developed Prosert\u00ae Preload Injector will win you over with its easy handling. After filling with the viscoelastic material, the injector is ready for use.<\/strong><\/p>\n

        \n
      • Controlled implantation thanks to precision screw thread<\/li>\n
      • Prosert\u00ae \u2013 one step \u201einto the bag\u201c<\/li>\n
      • Optimal lens fit, 100% preloaded<\/li>\n
      • Dynamic tip allows implantations with 2.0 \u2013 2.2 mm incisions<\/li>\n
      • Outer diameter of the injector tip: 1.78 mm<\/li>\n<\/ul>\n\t<\/div>\n\t\r\n\r\n\t
        \n\t\t\t<\/div>\n\t\r\n\t
        \n\t\t\t<\/div>\n\t\r\n\t
        \n
        <\/div>\n
        <\/div>\n
        <\/div>\n
        <\/div>\n <\/div>\n\t\r\n\t\t\t
        \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
        \n
        <\/div>\n
        <\/div>\n
        <\/div>\n
        <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
        \n\t\t\r\n\t
        \n\t\t\r\n\t
        \n\t\t

        Spherical standard intraocular lenses have been used in cataract surgery for many years. A number of manufacturers offer a large selection of these lenses. However, the disadvantage of using spherical lenses is that they cause certain optical defects that affect the quality of vision. Aspherical Primus-HD\u00ae intraocular lenses prevent these optical defects. This helps improve the general quality of vision, in particular due to their optimisation of contrast sensitivity and night vision.<\/p>\n\t<\/div>\n\t\r\n\r\n\t

        \n\t\t

        In spherical lenses, incident light passing through the periphery does not converge at the same point as the incident light passing through the centre. The reason for this is that the optical power of the lens rises as the distance of the incident light from the centre of the lens increases. This means that incident light falling in the periphery is more strongly refracted by the lens than incident light falling in the centre. Spherical aberration thus causes blurring in images with wide-open light beams, in other words when the pupils are widely dilated. This causes vision to be blurred. This defect can be eliminated by decreasing the curvature of the lens surfaces towards the edge. This is exactly what aberration correction Primus-HD\u00ae intraocular lenses offer.<\/p>\n\t<\/div>\n\t\r\n\t

        \n
        <\/div>\n
        <\/div>\n
        <\/div>\n
        <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
        \n\t\t\r\n\t
        \n\t\t\r\n\t\t\t
        \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t<\/div>\n\t\r\n\t
        \n\t\t\r\n\t\t\t
        \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
        \n
        <\/div>\n
        <\/div>\n
        <\/div>\n
        <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
        \n\t\t\r\n\t
        \n\t\t\r\n\t\t\t
        \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
        \n\t\t\r\n\t
        \n\t\t\r\n\t
        \n
        <\/div>\n
        <\/div>\n
        <\/div>\n
        <\/div>\n <\/div>\n\t\r\n\t
        \n\t\t

        In contrast, the aspherical Primus-HD\u00ae intraocular lenses converge all the incident light at the same point. This allows light rays that are far away from the centre of the lens to be focused at the same point as near or central incident light. This is a requirement for achieving the ideal vision sharpness, especially at night, when the pupil grows much larger in the dark and the passing light beams are wide open.<\/p>\n\t<\/div>\n\t\r\n\t

        \n
        <\/div>\n
        <\/div>\n
        <\/div>\n
        <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
        \n\t\t\r\n\t
        \n\t\t\r\n\t
        \n\t\t
        \n

        Modified C-loop<\/h4>\n<\/p><\/div>\n
          \n
        • Ensures lens adjustment to capsular bags of different sizes<\/li>\n
        • Ensures excellent centring and stability<\/li>\n<\/ul>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
          \n\t\t\r\n\t
          \n\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t\t\t
          \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
          \n\t\t\r\n\t
          \n\t\t\r\n\t
          \n\t\t
          \n

          Functionality<\/h4>\n<\/p><\/div>\n

          Implantation of the Primus-HD\u00ae via an incision size of 2.0 mm \u201einto the bag\u201c<\/p>\n

          The following description is merely a summary of the handling and does not replace the instructions for use.<\/span><\/p>\n

          Step 1: Wetting<\/strong>
          \nAt the beginning of the aspiration phase, fill in the viscoelastic material through the infusion opening to allow sufficient wetting. The injector remains in the holding container.<\/p>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t

          \n\t\t\r\n\t
          \n\t\t\r\n\t\t\t
          \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
          \n\t\t\r\n\t
          \n\t\t\r\n\t
          \n\t\t

          Step 2: Implantation preparation<\/strong>
          \nRemove the injector from the container when the surgeon is ready for the implantation.<\/p>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t

          \n\t\t\r\n\t
          \n\t\t\r\n\t\t\t
          \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
          \n\t\t\r\n\t
          \n\t\t\r\n\t
          \n\t\t

          Step 3: Implantation<\/strong>
          \nSlowly push the IOL in the direction of the injector tip by turning the screw handle clockwise until the front haptic has reached the bevel. Insert the injector tip with slot down (Bevel Down) through the incision deep into the capsular bag and release the lens by smoothly turning the screw handle further into the capsular bag.<\/p>\n

          Implantation via an incision size of 2.0 mm \u201einto the bag\u201c is possible<\/strong><\/p>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t

          \n\t\t\r\n\t
          \n\t\t\r\n\t\t\t
          \n\t\t\t\t\"\"\t\t\t<\/div>\n\t\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
          \n\t\t\r\n\t
          \n\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t
          \n\t\t\n\n\n\n\n\n\n\n\n\n\n\n\n
          Technical data<\/strong><\/td>\nPrimus-HD\u00ae \/ Primus-HD\u00ae Yellow<\/strong><\/td>\n<\/tr>\n
          IOL type<\/td>\nSingle piece<\/td>\n<\/tr>\n
          Material<\/td>\nHigh-purity, hydrophobic acrylic, glistening-free, grade \u201e0\u201c on the Miyata scale<\/td>\n<\/tr>\n
          Filter<\/td>\nUV-filter (Primus-HD\u00ae Yellow<\/strong> with blue light filter)<\/td>\n<\/tr>\n
          Lens type<\/td>\nPosterior convex, aspherical optics (aberration correcting -0.20 \u03bc)<\/td>\n<\/tr>\n
          Powers<\/td>\n-10.0 to +36.0 in 0.5 D increments, all strengths preloaded<\/td>\n<\/tr>\n
          A-constant*<\/td>\n118.9 (nominal)<\/td>\n<\/tr>\n
          Lens diameter<\/td>\n6.0 mm optic zone<\/td>\n<\/tr>\n
          Total diameter<\/td>\n13.00 mm<\/td>\n<\/tr>\n
          Haptic design and angularity<\/td>\nModified C-loop, 1.5\u00b0<\/td>\n<\/tr>\n
          Edge design<\/td>\n360\u00b0 ultra-sharp square edge, roughened edge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

          *The A constant is the basis for calculating the lens power.
          \nIt is recommended that these be customized based on the experience of the operating surgeon and the equipment used.<\/span><\/p>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t

          \n\t\t\t<\/div>\n\t\r\n\t
          \n\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t
          \n\t\t\n\n\n\n\n\n\n\n\n
          Optimized values for laser biometrics<\/strong><\/td>\nPrimus-HD\u00ae \/ Primus-HD\u00ae Yellow<\/strong><\/td>\n<\/tr>\n
          Nominal<\/td>\n118.9<\/td>\n<\/tr>\n
          Haigis<\/td>\na0=1.46 a1=0.40 a2=0.10<\/td>\n<\/tr>\n
          HofferQ<\/td>\npACD 5.68<\/td>\n<\/tr>\n
          Holladay<\/td>\nsf=1.91<\/td>\n<\/tr>\n
          SRK\/T<\/td>\n119.2<\/td>\n<\/tr>\n
          SRKII<\/td>\n119.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\r\n\t
          \n\t\t\t<\/div>\n\t\r\n\t
          \n\t\t\r\n\t
          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t
          \n\t\t
          \n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t\"\"\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t

          Ultra-pure premium acrylic, glistening-free, no sticking of the haptics, high light transmission.<\/p>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\r\n\t

          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t
          \n\t\t
          \n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t\"\"\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t

          Roughened lens edge, effectively prevents glare induced by the lens edge.<\/p>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\r\n\t

          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t
          \n\t\t
          \n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t\"\"\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t

          360\u00b0 contact with the posterior capsule.<\/p>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\r\n\t

          \n
          <\/div>\n
          <\/div>\n
          <\/div>\n
          <\/div>\n <\/div>\n\t\r\n\t
          \n\t\t
          \n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t\"\"\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t
          \n\t\t\t\t
          \n\t\t\t\t\t

          360\u00b0 ultra-sharp square edge design, increased barrier effect against LECs.<\/p>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\r\n\t<\/div>\n\t\r\n\t<\/div>\n\t","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":540,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-8","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"\nPrimus-HD\u00ae \/ Yellow - Ophthalmo [EN]<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Primus-HD\u00ae \/ Yellow - Ophthalmo [EN]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/\" \/>\n<meta property=\"og:site_name\" content=\"Ophthalmo [EN]\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-10T15:52:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/\",\"url\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/\",\"name\":\"Primus-HD\u00ae \/ Yellow - Ophthalmo [EN]\",\"isPartOf\":{\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg\",\"datePublished\":\"2018-02-21T17:36:36+00:00\",\"dateModified\":\"2021-11-10T15:52:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#primaryimage\",\"url\":\"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg\",\"contentUrl\":\"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg\",\"width\":1200,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/ophthalmo-pro.de\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Primus-HD\u00ae \/ Yellow\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ophthalmo-pro.de\/en\/#website\",\"url\":\"https:\/\/ophthalmo-pro.de\/en\/\",\"name\":\"Ophthalmo [EN]\",\"description\":\"Produkte f\u00fcr die Augenchirurgie\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ophthalmo-pro.de\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Primus-HD\u00ae \/ Yellow - Ophthalmo [EN]","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"en_US","og_type":"article","og_title":"Primus-HD\u00ae \/ Yellow - Ophthalmo [EN]","og_url":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/","og_site_name":"Ophthalmo [EN]","article_modified_time":"2021-11-10T15:52:26+00:00","og_image":[{"width":1200,"height":500,"url":"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/","url":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/","name":"Primus-HD\u00ae \/ Yellow - Ophthalmo [EN]","isPartOf":{"@id":"https:\/\/ophthalmo-pro.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#primaryimage"},"image":{"@id":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#primaryimage"},"thumbnailUrl":"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg","datePublished":"2018-02-21T17:36:36+00:00","dateModified":"2021-11-10T15:52:26+00:00","breadcrumb":{"@id":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ophthalmo-pro.de\/en\/primus-hd\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#primaryimage","url":"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg","contentUrl":"https:\/\/ophthalmo-pro.de\/en\/wp-content\/uploads\/sites\/5\/2020\/02\/Ophthalmo-Header-PrimusHD-2020-EN.jpg","width":1200,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/ophthalmo-pro.de\/en\/primus-hd\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/ophthalmo-pro.de\/en\/"},{"@type":"ListItem","position":2,"name":"Primus-HD\u00ae \/ Yellow"}]},{"@type":"WebSite","@id":"https:\/\/ophthalmo-pro.de\/en\/#website","url":"https:\/\/ophthalmo-pro.de\/en\/","name":"Ophthalmo [EN]","description":"Produkte f\u00fcr die Augenchirurgie","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ophthalmo-pro.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/pages\/8","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/comments?post=8"}],"version-history":[{"count":37,"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/pages\/8\/revisions"}],"predecessor-version":[{"id":714,"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/pages\/8\/revisions\/714"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/media\/540"}],"wp:attachment":[{"href":"https:\/\/ophthalmo-pro.de\/en\/wp-json\/wp\/v2\/media?parent=8"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}